pH Meter Jenway 3510
• Simultaneous readout of pH and temperature
• pH resolution to 3 decimal places
• 1, 2 or 3 point calibration
• Automatic or manual buffer selection
• Storage of up to 32 results
• RS232 connection to printer or PC via DataWay
• 3 year warranty
The 3510 is a versatile, simple to use pH, mV and temperature meter that is ideal for routine analysis. With up to three decimal place resolution and a choice of up to three calibration points the 3510 provides the user with added flexibility where future demands for enhanced performance may be required. A choice of pH calibration buffers to DIN, JIS and NIST standards can be used for automatic calibration, as well as manually entered buffer values. The pH measurement meter also has the ability to store up to 32 results.
pH Meter Jenway 3520
• Ideal for quality control and GLP applications
• Up to 3 decimal place resolution
• 1, 2 or 3 point pH calibration
• Automatic or manual buffer selection
• Multiple language options
• Storage of up to 500 results
• RS232 connection to printer or PC or infra red (IrDA) communication
• GLP compliant
• 3 year warranty
The 3520 dynamic pH/mV meter offers research grade specifications with a comprehensive range of features and functions, making it suitable for the broadest range of research, general laboratory, QC and GLP based applications. The built in data logger can store, print or output readings based on a wide range of trigger options, making this model suitable for monitoring and controlling pH levels.
Product Description
Parameter | 3510 | 3520 |
pH range | – 2.000 to + 19.999 | – 2.000 to + 20.000 |
pH resolution | 0.001 0.01 0.1 | 0.001 0.01 0.1 |
pH accuracy | ± 0.003 | ± 0.003 |
Calibration | User selec table 1, 2 or 3 point | User selec table 1, 2 or 3 point |
Automatic buffer recognition | Jenway (2.00, 4.00, 7.00, 9.20 and 10.00), DIN, NIST, JIS | Jenway (2.00, 4.00, 7.00, 9.20 and 10.00), DIN, NIST, JIS |
mV range | ± 1999.9mV | ± 1999.9mV |
mV resolution | 0.1/ 1mV | 0.1/ 1mV |
mV accuracy | ± 0.2mV | ± 0.2mV |
Temperature range | – 10 to 105°C | – 10 to 105°C |
Temperature resolution | 0.1°C | 0.1°C |
Temperature accuracy | ± 0.5°C | ± 0.5°C |
ATC range | 0 to 100°C | 0 to 100°C |
Alarm points | N/A | – 2.000 to 19.999pH |
GLP | N/A | Calibration reminder interval (1 to 999hrs) Alarm outputs (open collector and audible). Security code protected data |
Outputs | Analogue and RS232 | Analogue, RS232 and IrDA |
Connector | BNC | BNC |
Power | 9V AC ± 10 @ 50/ 60Hz | 9V AC ± 10 @ 50/ 60Hz |
Size (l x w x d) | 210 x 250 x 55mm | 210 x 250 x 55mm |
Weight | 850g | 850g |
- Quality for every small pieces
- work with your new equipment
- AFTER SALES SERVICE
- EMAIL: info@modernscientific.net / PHONE : 01021600212