gallery-item

pH Meter Jenway 3510

• Simultaneous readout of pH and temperature
• pH resolution to 3 decimal places
• 1, 2 or 3 point calibration
• Automatic or manual buffer selection
• Storage of up to 32 results
• RS232 connection to printer or PC via DataWay
• 3 year warranty

The 3510 is a versatile, simple to use pH, mV and temperature meter that is ideal for routine analysis. With up to three decimal place resolution and a choice of up to three calibration points the 3510 provides the user with added flexibility where future demands for enhanced performance may be required. A choice of pH calibration buffers to DIN, JIS and NIST standards can be used for automatic calibration, as well as manually entered buffer values. The pH measurement meter also has the ability to store up to 32 results.

 

  • gallery-item
  • gallery-item

 

pH Meter Jenway 3520

• Ideal for quality control and GLP applications
• Up to 3 decimal place resolution
• 1, 2 or 3 point pH calibration
• Automatic or manual buffer selection
• Multiple language options
• Storage of up to 500 results
• RS232 connection to printer or PC or infra red (IrDA) communication
• GLP compliant
• 3 year warranty

The 3520 dynamic pH/mV meter offers research grade specifications with a comprehensive range of features and functions, making it suitable for the broadest range of research, general laboratory, QC and GLP based applications. The built in data logger can store, print or output readings based on a wide range of trigger options, making this model suitable for monitoring and controlling pH levels.

Product Description
Parameter 3510 3520
pH range – 2.000 to + 19.999 – 2.000 to + 20.000
pH resolution 0.001 0.01 0.1 0.001 0.01 0.1
pH accuracy ± 0.003 ± 0.003
Calibration User selec table 1, 2 or 3 point User selec table 1, 2 or 3 point
Automatic buffer recognition Jenway (2.00, 4.00, 7.00, 9.20 and 10.00), DIN, NIST, JIS Jenway (2.00, 4.00, 7.00, 9.20 and 10.00), DIN, NIST, JIS
mV range ± 1999.9mV ± 1999.9mV
mV resolution 0.1/ 1mV 0.1/ 1mV
mV accuracy ± 0.2mV ± 0.2mV
Temperature range – 10 to 105°C – 10 to 105°C
Temperature resolution 0.1°C 0.1°C
Temperature accuracy ± 0.5°C ± 0.5°C
ATC range 0 to 100°C 0 to 100°C
Alarm points N/A – 2.000 to 19.999pH
GLP N/A Calibration reminder interval (1 to 999hrs) Alarm outputs (open collector and audible). Security code protected data
Outputs Analogue and RS232 Analogue, RS232 and IrDA
Connector BNC BNC
Power 9V AC ± 10 @ 50/ 60Hz 9V AC ± 10 @ 50/ 60Hz
Size (l x w x d) 210 x 250 x 55mm 210 x 250 x 55mm
Weight 850g 850g

 

 

 

 

 

 

 

 